How to
Watch a measurement over minutes or hours
Chart a frequency, voltage or duty cycle over time, and save the log.
- Start the signal and press Run.
- Press Trend. The window charts one measurement from every capture.
- Choose the Measurement: frequency, peak to peak, mean, RMS or duty cycle. The distortion figures (THD, SNR, SINAD, SFDR, ENOB) are logged while Distortion is on under Spectrum.
- Leave it running. The window gives the number of readings, how long it has been logging, and the minimum, mean, maximum and standard deviation.
- Press Save CSV in the window to keep the log for a spreadsheet.
Ideas: a battery voltage running down, a clock drifting as it warms up, a motor’s speed under load.